"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [http://www.apcupsd.org/]
 
"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [http://www.apcupsd.org/]
 +
</blockquote>
  
 
==Installation==
 
==Installation==

Latest revision as of 17:58, September 16, 2014

sys-power/apcupsd


Source Repository:Repository:Gentoo Portage Tree


Summary: APC UPS daemon with integrated network-based remote shutdown


News

Drobbins

ARM Rebuild

ARM systems will use new stage3's that are not compatible with earlier versions.
2015-06-27 by Drobbins
Drobbins

ABI X86 64 and 32

Funtoo Linux has new 32-bit compatibility libraries inherited from Gentoo. Learn about them here.
2015-06-18 by Drobbins
Drobbins

Pre-built kernels!

Funtoo stage3's are now starting to offer pre-built kernels for ease of install. read more....
2015-05-12 by Drobbins
More...

APC UPS Daemon

Tip

We welcome improvements to this page. To edit this page, Create a Funtoo account. Then log in and then click here to edit this page. See our editing guidelines to becoming a wiki-editing pro.


"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [1]

Installation

Emerging

Emerge No results:

# emerge apcupsd

Configuration and Runlevel Registration

Edit your /etc/apcupsd/apcupsd.conf properly.

To start apcupsd, run the following:

# /etc/init.d/apcupsd start

To add apcupsd to the appropriate runlevels, execute the following commands:

# rc-update add apcupsd default
 * service apcupsd added to runlevel default
# rc-update add apcupsd.powerfail shutdown
 * service apcupsd added to runlevel shutdown

Check UPS status

Finally, to check on the status of acpupsd, run the following:

# apcaccess status
# tail -f /var/log/apcupsd.events