== What is apcupsd? ==
+
 
 
"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [http://www.apcupsd.org/]
 
"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [http://www.apcupsd.org/]
  

Revision as of 15:10, June 27, 2014

sys-power/apcupsd


Source Repository:Gentoo Portage Tree

Summary: APC UPS daemon with integrated network-based remote shutdown


News

Drobbins

Pre-built kernels!

Funtoo stage3's are now starting to offer pre-built kernels for ease of install. read more....
12 May 2015 by Drobbins
Drobbins

Better Experiences: Ego and Vim

Info on Funtoo's new personality tool called 'ego', and user-focused updates to vim's defaults.
27 April 2015 by Drobbins
Drobbins

How We're Keeping You At the Center of the Funtoo Universe

Read about recent developments that keep you, our users, at the forefront of our focus as Funtoo moves forward.
10 April 2015 by Drobbins
View More News...

APC UPS Daemon

Tip

This is a wiki page. To edit it, Create a Funtoo account. Then log in and then click here to edit this page. See our editing guidelines to becoming a wiki-editing pro.


"Apcupsd can be used for power mangement and controlling most of APC's UPS models on Unix and Windows machines. Apcupsd works with most of APC's Smart-UPS models as well as most simple signalling models such a Back-UPS, and BackUPS-Office. During a power failure, apcupsd will inform the users about the power failure and that a shutdown may occur. If power is not restored, a system shutdown will follow when the battery is exhausted, a timeout (seconds) expires, or runtime expires based on internal APC calculations determined by power consumption rates. Apcupsd is licensed under the GPL version 2." [1]

Installation

First, emerge sys-power/acpupsd (package not on wiki - please add):

# emerge apcupsd
# equery f apcupsd

Configuration and Runlevel Registration

Edit your /etc/apcupsd/apcupsd.conf properly.

To start apcupsd, run the following:

# /etc/init.d/apcupsd start

To add apcupsd to the appropriate runlevels, execute the following commands:

# rc-update add apcupsd default
 * service apcupsd added to runlevel default
# rc-update add apcupsd.powerfail shutdown
 * service apcupsd added to runlevel shutdown

Check UPS status

Finally, to check on the status of acpupsd, run the following:

# apcaccess status
# tail -f /var/log/apcupsd.events